- Suitable for use on Coaxial, Telephone, CATV, CCTV,
Power cable etc. |
- Maximum Range : 3.2~20,000m (10.4ft ~65,000ft) for
Coaxial cables
( * Maximum testable cable length will vary with pulse
width and cable type) |
|
- Two active cursors with individual control |
| -
Changeable zero point |
| -
Ease of use: single key functions |
|
- Non-volatile memory for storing measurement data up
to 100 waveforms |
|
- Useable battery time display |
|
- Built-in library of 77 cables for fast and easy selection
of VOP |
|
- Waveform zoom capabilities |
| -
Waveform trace and diagnosis |
|
- Automatic event search |
| -
Low power consumption |
| -
Efficient power management |
| -
Windows S/W : NanoWaveTM |
| -
Rugged and waterproof packing |
|
- Optional spare battery double operating time |
|
- CE & FCC certified |
|
|
Dimensions |
Dimensions |
267mm (10.5")
x 247mm (9.7") x 127mm (5") |
Net
Weight |
3.3㎏ (7.2lbs) |
|
Interface |
User
interface |
320x240 pixel
back-lit LCD |
Maximum
storage capacity |
100 waveforms
|
Internal
Memory |
256Kbyte
(maximum waveforms storage capacity is up to 100) |
Communication
port |
RS-232C,
38,400 baud rate (1 start bit, 8 data bits, 1 stop bit and
no parity ) |
| Output
impedance |
Automatic
output impedence control of 25, 50, 75, 100, 125 & 150
Ω |
| Gain |
O to 66dB
or better, maximum sensitivity 1mV
(full scale) |
| Input
bandwidth |
300MHz |
| Effective
sampling rate |
1GS/s |
| Screen
update rate |
Maximum 3
times per second |
| VOP(PVF) |
Variable
from30.0 to 99.9%( in 0.1% steps)
V : 90 to 300m/us
V/2 : 45 to 150m/us |
|
OperatingPower |
Battery |
12V Nickel-Metal
Hydride Battery(4000 mAh) |
Adaptor |
DC 12~14V
/ 1A Adaptor |
Connector
|
BNC Female
|
Operating
time |
6 hours |
Recharge
time |
4 hours |
|
Performance |
Measurement
range |
3.2m ~ 20,000m
(10.4ft ~ 65,000ft) for Coaxial cables |
Minimum
display resolution |
10cm (variable
up to 50m) |
| Accuracy
|
±0.1% of
reading ±0.1m for Coaxial cables |
| Test Mode
|
L1, L1&M,
L1-M, M |
| Pulse
width |
5,15,45,100,200,500,1000,2000,5000,10000㎱ |
|
Environment |
Operating
temperature |
-15℃(+5°F)
~ +55 ℃(131°F) |
Storage
temperature |
-20 ℃('-4°F)
~ +70 ℃(158°F) |
Humidity |
< 95% |
| |
The Advanced Waveform TDR(Model
No.:mTDR-070) is suitable for use on installation, maintenance
or fault finding (complete open & short, partial open
& short, loading coils, loose connection, broken lines
etc..) along with any type of metallic cables such as CATV,
CCTV, Coaxial cables, Power cable, Telephone line, UTP cables
whatever consists of at least two metallic conductors. |
| |
| To
be used for many kinds of cables |
| -
Coaxial cable network maintenance
|
| - CATV Network
maintenance |
| - Electric
power distribution |
| - maintenance |
| - Telephony
Network maintenance |
| - LAN Network
maintenance |
| - Security
cable maintenance |
|
 |
| To
be used in many industrial sites |
| Telephone
company, ISP(Internet Service Provider), CATV
company,
HFC network maintenance company,
LAN installer or maintenance company,
Power plant company, Chemical company,
Ship-builder, Large-sized vessel or Warship
Communication unit in military
Large-sized factory,Subway station & Railroad
company
wherever there are any metallic cables installed
and need to maintain them |
|
|
 |
 |
 |
| To find any problem on the telephone line
in the wall, ceiling or underground |
To identify alive cable modem users without visiting
each home in the CATV network |
To find any problem on the power, telephone or UTP
cable in the wall or ceiling in the subway or railway
stations etc.. |
 |
 |
 |
| To find any problem on the power, telephone
or UTP cable in the wall or ceiling at the airport building
etc. |
To find any problem on the emergency telephone line
or power cable installed in the bridge or highway etc.. |
To find any problem on the emergency telephone line,
heating cable or power cable installed in the tunnel
etc.. |
 |
 |
 |
| To find any problem on any cable installed
along with the pipe line etc.. |
To find any problem on the telephone line, UTP cable
or power cable installed in the large-sized factory,
power plant or water purification plant etc.. |
To find any problem on the emergency communication
line or power cable installed in the underground tunnel
etc.. |
 |
 |
 |
| To find any problem on the communication
line or power cable installed in large-sized vessel
or warship, submarine etc.. |
To find any problem on the emergency telephone line
or power cable temporarily installed in the construction
or engineering work sites etc.. |
To find any problem on the heating cable installed
in the sauna or snow melting sites etc.. |
 |
 |
 |
| To find any problem on the communication
line or data transmission cable between radar and headquarter
or communication unit in military etc.. |
To find any problem on the power cable installed in
the underground such as cables for street light etc..
|
To find any problem on the coaxial cable for CCTV
or security camera etc.. |
 |
|
|
| To check length of cable at retailer wholesaler
or cable manufacturer etc.. |
|
|
|
| |
Standard Accessories |
 |
| |
① 2m test leads (pin type) |
| |
② 30cm test leads (pin type) |
| |
③ Alligator clip (BLACK/RED) |
| |
④ RS 232C serial communication cable |
| |
⑤ DC 15V / 1A adaptor |
| |
⑥ BNC to F connector |
| |
⑦ BNC to BNC connector |
| |
⑧ User’s manual |
| |
⑨ NanoWave™ installation CD |
| |
⑩ Soft carrying bag |
| |
* A battery pack is built into the instrument
|
| |
Optional Accessories |
| |
① External spare battery |
| |
② Male BNC to female RJ45 adaptor |
| |
③ 12V Cigarette lighter charger |
| |
④ 8m / 75Ω coaxial cable |
| |
| |
|