¹«Á¦ ¹®¼
|
|
 |
 |
 |
 |
 |
 |
| The Advanced
Waveform TDR(Model No.:mTDR-070) is a high-end TDR
instrument designed to meet today's most demanding
network cabling problems. Advancing beyond the numeric
readout, the Advanced Waveform TDR(Model No.:mTDR-070)
displays the actual waveform or "signature"
of the cable. Keeping to its traditional ways, the
Advanced Waveform TDR(Model No.:mTDR-070) displays
the actual waveform or signature of the cable thereby
enabling engineers and technicians to pinpoint any
impedance reflections along the length of the cable |
|
|
 |
|
|
| |
|
 |
 |
Suitable
for use on Coaxial, Telephone, CATV, CCTV, Power cable etc. |
 |
Maximum
Range : 3.2~20,000m (10.4ft ~65,000ft) for Coaxial cables
( * Maximum testable cable length will vary with pulse width
and cable type) |
| |
 |
Two active cursors
with individual control |
 |
Changeable zero point
|
 |
Ease of use: single
key functions |
 |
Non-volatile memory
for storing measurement data up to 100 waveforms |
 |
Useable battery time
display |
 |
Built-in library
of 77 cables for fast and easy selection of VOP |
 |
Waveform zoom capabilities |
 |
Waveform trace and
diagnosis |
 |
Automatic event search |
 |
Low power consumption
|
 |
Efficient power management
|
 |
Windows S/W : NanoWaveTM |
 |
Rugged and waterproof
packing |
 |
Optional spare battery
double operating time |
 |
CE & FCC certified |
| |
|
|
| |
|
| |
 |
| |
| |
Dimensions
|
Dimensions |
267mm
(10.5") x 247mm (9.7") x 127mm (5")
|
Net
Weight |
3.3§¸
(7.2lbs) |
|
Interface |
User interface |
320x240 pixel back-lit
LCD |
| Maximum
storage capacity |
100 waveforms |
| Internal
Memory |
256Kbyte (maximum
waveforms storage capacity is up to 100) |
| Communication
port |
RS-232C, 38,400
baud rate (1 start bit, 8 data bits, 1 stop bit and
no parity ) |
| Output
impedance |
Automatic output
impedence control of 25,50,75,100,125 & 150 §Ù |
| Gain |
O to 66dB or better,
maximum sensitivity 1mV (full scale) |
| Input
bandwidth |
300MHz |
| Effective
sampling rate |
1GS/s |
| Screen
update rate |
Maximum 3 times
per second |
| VOP(PVF) |
Variable from30.0
to 99.9%( in 0.1% steps)
V : 90 to 300m/us
V/2 : 45 to 150m/us |
|
OperatingPower |
Battery |
12V Nickel-Metal
Hydride Battery(4000 mAh) |
| Adaptor |
DC 12~14V / 1A Adaptor
|
| Connector |
BNC Female |
| Operating
time |
6 hours |
| Recharge time |
4 hours |
|
Performance |
Measurement
range |
3.2m
~ 20,000m (10.4ft ~ 65,000ft) for Coaxial cables |
Minimum
display resolution |
10cm
(variable up to 50m) |
Accuracy
|
¡¾0.1% of reading
¡¾0.1m for Coaxial cables |
| Test Mode |
L1, L1&M, L1-M,
M |
| Pulse width |
5,15,45,100,200,500,1000,2000,5000,10000§À |
Environment |
Operating
temperature
|
-15¡É(+5¡ÆF)
~ +55 ¡É(131¡ÆF)
|
Storage
temperature |
-20
¡É('-4¡ÆF) ~ +70 ¡É(158¡ÆF) |
Humidity |
<
95% |
|
| * Except where otherwise
stated, this specifications apply an ambient temperature of
20¡É(68¢µ) |
|
|
| |
|
| |
 |
| |
| |
| The Advanced Waveform TDR(Model
No.:mTDR-070) is suitable for use on installation, maintenance
or fault finding (complete open & short, partial open
& short, loading coils, loose connection, broken lines
etc..) along with any type of metallic cables such as
CATV, CCTV, Coaxial cables, Power cable, Telephone line,
UTP cables whatever consists of at least two metallic
conductors. |
| |
| |
 |
To
be used in many industrial sites |
| |
Telephone
company, ISP(Internet Service Provider), CATV company,
HFC network maintenance company,
LAN installer or maintenance company,
Power plant company, Chemical company,
Ship-builder, Large-sized vessel or Warship
Communication unit in military
Large-sized factory,Subway station & Railroad
company
wherever there are any metallic cables installed
and need to maintain them |
| To
be used for many kinds of cables |
-
Coaxial cable network maintenance
- CATV Network maintenance
- Electric power distribution
- maintenance
- Telephony Network maintenance
- LAN Network maintenance
- Security cable maintenance |
| |
| |
|
| |
 |
 |
 |
| To find any problem on the telephone
line in the wall, ceiling or underground |
To identify alive cable modem
users without visiting each home in the CATV network
|
To find any problem on the power,
telephone or UTP cable in the wall or ceiling in
the subway or railway stations etc.. |
 |
 |
 |
| To find any problem
on the power, telephone or UTP cable in the wall
or ceiling at the airport building etc.. |
To find any problem
on the emergency telephone line or power cable installed
in the bridge or highway etc.. |
To find any problem
on the emergency telephone line, heating cable or
power cable installed in the tunnel etc.. |
 |
 |
 |
| To find any problem
on any cable installed along with the pipe line
etc.. |
To find any problem
on the telephone line, UTP cable or power cable
installed in the large-sized factory, power plant
or water purification plant etc.. |
To find any problem
on the emergency communication line or power cable
installed in the underground tunnel etc..
|
 |
 |
 |
| To find any problem on the communication
line or power cable installed in large-sized vessel
or warship, submarine etc.. |
To find any problem on the emergency
telephone line or power cable temporarily installed
in the construction or engineering work sites etc.. |
To find any problem on the heating
cable installed in the sauna or snow melting sites
etc.. |
 |
 |
 |
| To find any problem on the communication
line or data transmission cable between radar and
headquarter or communication unit in military etc.. |
To find any problem on the power
cable installed in the underground such as cables
for street light etc..
|
To find any problem on the coaxial
cable for CCTV or security camera etc..
|
 |
|
|
| To check
length of cable at retailer wholesaler or cable
manufacturer etc.. |
|
|
|
|
|
| |
 |
| |
 |
Standard Accessories |
 |
| ¨ç |
2m test leads (pin type) |
| ¨è |
30cm test leads (pin type) |
| ¨é |
Alligator clip |
| ¨ê |
RS 232 serial communication cable |
| ¨ë |
DC 12~14V / 2A adaptor |
| ¨ì |
BNC to F connector |
| ¨í |
BNC to BNC connector |
| ¨î |
User¡¯s manual |
| ¨ï |
NanoWave¢â installation CD |
| ¨ð |
Shoulder strap |
| ¨ñ |
Soft carrying bag |
| |
* A battery pack
is built into the instrument |
| |
|
LAN Cable Tester with Standard
Accessories |
| |
|
 |
 |
Optional Accessories |
| ¨ç |
External spare battery |
| ¨è |
Male BNC to female RJ45 adaptor |
| ¨é |
12V Cigarette lighter charger |
| ¨ê |
8m / 75¥Ø coaxial cable |
| |
|
Optional Accessories for LAN
Cable Tester |
| |
|
|
| |
|
| |
|
 |
|
| |