Multi-function cable fault locator (Model No.: NCM-1000)
is an excellent and highly accurate hand-held measuring
instrument to check any problem and distance to
the event on the cable by using 3 different cable
testing methods: MTDR (Metallic Time-Domain Reflectometer),
RFL (Resistance Fault Locator) and Capacitance measurement.
It also provides additional two functions, found
in DMMs (Digital Multi-Meters), measuring DC voltage
and resistance. |
|
|
 |
|
|
| |
|
 |
| |
NanoTronix's
Multi-function cable fault locator (Model No.: NCM-1000)
is an excellent and highly accurate portable measuring
instrument to check problem and distance to events on
cable using three testing methods: Metallic Time-Domain
Reflectometer(MTDR), Resistance Fault Locator(RFL) and
Open mode.
It also provides additional three functions, found in
DMMs (Digital Multi-Meters):
DC voltage measurement, resistance measurement and capacitance
measurement.
The MTDR shows the continuity of characteristic impedance
along the cable under test applying electrical pulses,
which is ideal for checking faults (such as complete
open & short, partial open & short, loose connection,
broken lines, loading coil etc.) on any cables which
consist of at least two metallic conductors (such as
telephone lines, power lines, UTP networks, CATV or
CCTV, lines etc.).
The RFL figures out the total length and distance to
the insulation resistance reduction point on clables
with three metallic conductors. It calculates the distance
and insulation resistance with high accuracy via Murray
Loop Testing method.
The Open mode calculates the total length or distance
to an open circuit of extremely long cables up to 100km.
It measures the total capacitance of the
cable under test and converts it to distance based on
the information about capacitance per unit length of
the cable.
NCM-1000 performs all the measurement process automatically
and
displays the results in the graphic and tabular forms
through a color
graphic TFT LCD screen with 640x480 pixel resolution.
The instrument design allows the user to easily determine
the conditions
of the cable being measured.
NCM-1000 is an excellent instrument for the cable installation,
maintenance,
repair after fault finding regardless of the cable installation
environment. |
| |
|
|
| |
|
 |
 |
TDR mode |
 |
Bridge mode |
 |
Capacitance mode |
 |
Voltage mode |
 |
Resistance mode |
 |
Easy to use, Lightweight
and compact |
 |
6.4" TFT Color
LCD display |
 |
RS232C upload port |
 |
CD indicator for battery
time |
 |
Selectable auto-off
time |
 |
Selectable auto-off
time |
 |
Waveform trace and
diagnosis |
 |
Rugged and waterproof
packing |
 |
Optional spare battery
double operating time |
 |
PC software for further
analyzing, reporting and printing |
| |
|
|
| |
| |
 |
| |
| |
| NCM-1000 |
| MTDR
Mode |
Measurement
range |
3.2m
~ 20,000m (10.4ft ~ 65,000ft) for Coax. |
| *
Maximum testable cable length will vary with pulse width
and cable type |
| Maximum display resolution |
10cm
(Variable up to 50m) |
| Accuracy |
0.1%
¡¾ 0.1m of reading for Coax. |
| *
Accuracy will vary with VOP of cable being tested |
| Test mode |
L1, L1&M,
L1-M, M |
| Pulse width |
5ns,
15ns, 50ns, 100ns, 200ns, 500ns, 1§Á, 2§Á, 5§Á, 10§Á |
| Maximum storage capacity |
100 waveforms |
| Output impedance |
Automatic
output impedance control of 25, 50, 75, 100, 125, 150§Ù |
Input bandwidth
|
300§Ö |
| Effective sampling
rate |
1GS/s |
| Gain |
0 to
66dB or better, maximum sensitivity 1mV
(full scale) |
| Screen update rate
|
Maximum
3 times per second |
VOP (PVF)
|
Variable
from 30.0 to 99.9% (in 0.1% step)
V: 90~300 m/§Á
V/2: 45~150 m/§Á |
| RFL
Mode |
Maximum loop resistance
|
10k§Ù |
| Loop
resistance |
1§Ù |
| Maximum
insulation resistance |
20M§Ù |
| Insulation
resistance resolution |
10k§Ù |
| Distance
accuracy |
1% |
| Distance
resistance |
1m |
| Insulation
resistance accuracy |
5% |
Open
Mode
(capacitance measurement) |
Maximum capacitance |
20§Þ |
| Accuracy |
| Range |
Accuracy |
| up to 10nF |
3% |
| up to 1§Þ |
5% |
| up to 20§Þ |
10% |
|
| Distance
Resolution |
1m |
| Voltage
measurement |
current type |
DC |
| Maximum Voltage |
300V DC |
| Accuracy |
| Range |
Accuracy |
| up to 10V |
1% ¡¾ 0.5V |
| up to 50V |
2% |
| up to 300V |
3% |
|
| Resistance
measurement |
Maximum
Resistance |
100M§Ù |
| Accuracy |
| Range |
Accuracy |
| up to 10k§Ù |
1% ¡¾ 5§Ù |
| up to 100k§Ù |
1% |
| up to 1M§Ù |
3% |
| up to 10M§Ù |
5% |
| up to 100M§Ù |
5% |
|
| General
specifications |
Display type
|
6.4" Color
TFT LCD |
| Internal memory |
2MB |
| Communication port |
RS-232C compatible
( 1 start bit, 8 data bits, 1 stop bit, no parity and
38,400 baud rate) |
| Power supply |
7.6V Li-ion chargeable
battery pack 8,800mAh, /AC adapter |
Battery life
|
7 hours (extendable
up to 14 hours with optinal spare battery |
| Recharging time |
7 hours |
| Operating temperature |
- 10¡É(+14¢µ) ~ +50¡É(122¢µ) |
Storage temperature
|
- 20¡É(-4¢µ) ~ +70¡É(158¢µ) |
| Relative humidity
|
<95% |
| Weight |
2.7§¸(5.9lbs) |
| Dimensions
|
267mm(10.5")
x247mm(9.7") x 127mm(5") |
| * Except
where otherwise stated, this specifications apply an
ambient temperature of 20¡É(68¢µ). |
|
|
|
| |
|
 |
|
| |